Bulletin number: 230 Products affected: D700E Description: Transputer error flag set in the TDS or a utility Component: The examples and tutorial Date: Tue May 15 17:00:00 GMT 1990 ----- The document does not mention the possibility that the TDS itself or a utility package may fail by setting the transputer error flag. This should not happen, but if it does the user should press r to reboot and the occurrence should be reported to INMOS (via an FAE) with the following additional information: The identity of the UTIL being run, if any, The absolute and relative values of the instruction pointer at halt (displayed on the screen before the TDS reboots). With this information a person with access to the source of the TDS or utility can discover where the error was caused. The following bugs mentioned in the TDS2 buglist (Rev 5) have been cured (or are irrelevent) in TDS3: 15 18 33 43 60 209